Pharmaceutical stability test chambers
XCH CSD Series Biomedical stability pharmaceutical chambers, Two case independent control,CSD series, A Chamber has three functions: temperature, humidity and illumination. near ultraviolet lamp tube can be optional,Meet the requirements of the stability test guidelines of the 2020 edition of pharmacopoeia; B Chamber can only control and record temperature and humidity.
Key Features:
Stability Test System:
- CSD series: A with function of illumination, Illumination Range: 100 ~ 8000Lux,Near Ultraviolet Range: 0.84 ~ 5w / m2 ,Illuminance deviation: 4500±500Lux
- Structure Design: Adopt the latest airduct system design achieves good uniform of temperature and humidity form different parts inside the chamber.
- Insulation material: Integral polyurethane foam technology, with good heat preservation and moisture retention performance.
- Chamber Material: The liner is made of mirror stainless steel 304, no pollution source, easy to clean
- Refrigerating System: The imported fully enclosed industrial compressor, long-life, low noise
Temperature Control and Safety Monitoring:
- Temperature Fluctuation ≤ ±0.5℃
- Temperature Deviation ≤ ±1.0℃
- Installed Power: AC220V±10% 50HZ
- Environment temperature: +5~35℃
Humidity Control:
- Humidity Fluctuation ≤ ±3%RH
- Humidity Deviation ≤ ±3%RH
- Humidity System: Original imported capacitive humidity sensor, direct detection of humidity,maintenance-free
Easy to Operate:
- Control System: Two sets color touch screen temperature and humidity controller,High control accuracy,With three levels permission,audit trail
- Illumination System: Equipped with illumination sensor,direct illumination display, equipped with illumination storage and printing system
- Data Record: Equipped with data collection system conform to GMP requirements,Two sets Needle micro printer and USB output port as standard
Safety Control:
- Safety device: compressor overheat and overpressure overload protection, Fan overheat protection、water shortage protection.
- Live Alarm: Temperature and humidity upper limit deviation alarm, independent overtemperature alarm.
- Dual Protection: Equipped with double insurance dry fire protection system, equipped with independent overtemperature protection system, can automatically cut off the power supply
- Meet a criterion: Meet ICHQ1A(R2)、Q1B、Chinese Pharmacopoeia 2020 edition
- SMS alarm: Optional

Stability chamber specification:
MODEL |
TEMP CONTROL RANGE(℃) |
HUMIDITY CONTROL RANGE |
CAPACITY(L) |
INTER DIMEN |
EXTER DIMEN |
POWER(KW) |
Shelf (Standard) |
Shelf (Standard) |
Remarks |
XCH-320SD |
10 ~ 65 |
20 ~ 95% |
150 |
680×500×460 |
840×840×1880 |
2.5 |
2 |
Up |
A box (temperature + humidity) |
10 ~ 65 |
20 ~ 95% |
150 |
680×500×460 |
2.5 |
2 |
Down |
Box B (Temp + Humidity) |
||
XCH-520SD |
10 ~ 65 |
20 ~ 95% |
250 |
600×500×830 |
1560×870×1650 |
3.0 |
3 |
Left |
A box (temperature + humidity) |
10 ~ 65 |
20 ~ 95% |
250 |
600×500×830 |
3.0 |
3 |
Right |
Box B (Temp + Humidity) |
||
XCH-620SD |
10 ~ 65 |
20 ~ 95% |
300 |
600×500×1000 |
1560×870×1820 |
3.2 |
3 |
Left |
A box (temperature + humidity) |
10 ~ 65 |
20 ~ 95% |
300 |
600×500×1000 |
3.2 |
3 |
Right |
Box B (Temp + Humidity) |
||
Double chamber, independent control |
MODEL |
TEMP CONTROL RANGE(℃) |
HUMIDITY CONTROL RANGE |
CAPACITY(L) |
INTER DIMEN |
EXTER DIMEN |
POWER |
Shelf (Standard) |
Shelf (Standard) |
Remarks |
XCH-320CSD |
15 ~ 65 |
20 ~ 95% |
150 |
680×500×460 |
840×840×1880 |
2.5 |
2 |
Up |
A box (temperature + humidity + visible light) |
680×500×460 |
840×840×1880 |
2.5 |
2 |
Down |
Box B (Temp + Humidity) |
||||
XCH-520CSD |
15 ~ 65 |
20 ~ 95% |
250 |
600×500×830 |
1560×870×1650 |
3.0 |
3 |
Left |
A box (temperature + humidity + visible light) |
680×500×460 |
1560×870×1650 |
3.0 |
3 |
Right |
Box B (Temp + Humidity) |
||||
XCH-620CSD |
15 ~ 65 |
20 ~ 95% |
300 |
600×500×1000 |
1560×870×1820 |
3.2 |
3 |
Left |
A box (temperature + humidity + visible light) |
600×500×1000 |
1560×870×1820 |
3.2 |
3 |
Right |
Box B (Temp + Humidity) |
||||
|
Double chamber, independent control |
Remark:
CSD series A equipped with temperature, humidity, visible light and NUV light four functions,Illumination measurement standard with visible and near ultraviolet sensors.Visible and near ultraviolet values are automatically printed and stored;Visible Range: 100 ~ 8000Lux,4500±500Lux,The total illumination of the light test shall not be less than 1.2×106 Lux·hr Near ultraviolet range: 0.84 ~ 5w/㎡,Near ultraviolet energy shall not be less than 200w·hr//㎡
Application:
XCH-SD series Medicine Stability Testing Chamber Dual Chamber provide long-term stable temperature, humidity and light environment to detect the expiration date of drugs, used for long-term test, accelerated test, high humidity test, strong light irradiation test and drug stability test.
Advantages:
Sensitive, small system error
Two boxes of independent control
No pollution source and is easy to clean
Low cost