Walk in Chamber is a stability chamber by digital, adopt newly airway system designed achieves uniform of temperature and humidity form different parts inside the chamber. The inner wall and duct plate are made of stainless steel 304. Observation window of hollow tempered glass with electrothermal film.

Please leave a message to tell us your needs, we will reply you within 2 hours.

Categories
  • reach in chamber, walk in environmental chamber, Walk-In Stability test Chamber
    Walk-in Stability Test Chamber 15000SD
    Temp.:20℃~45℃, Humidity Range: 40 - 80%RH
    XCH-15000SD Series humidity and temperature controlled chamber, newly airway system designed achieves uniform of temperature and humidity form different parts inside the chamber. The inner wall and duct plate are made of stainless steel 304. Observation window of hollow tempered glass with electrothermal film.


    Model:XCH-15000SD

    Temperature Range:20~45℃

  • Walk-In Stability Chamber, Walk-In Stability test Chamber
    Walk-in Stability Test Chamber 40000SD
    Temp.:20~45℃, Humidity:20/40~80%RH
    The XCH-40000SD Series newly airway system designed achieves uniform of temperature and humidity form different parts inside the chamber. The inner wall and duct plate are made of stainless steel 304. Observation window of hollow tempered glass with electrothermal film.


    Temperature Range: 20~ 45℃

    Temperature Fluctuation≤ ±0.5℃

    Temperature Deviation≤ ±1.0℃

    Humidity Range40~80%RH(or 2080%RH);

    Humidity Deviation≤ ±3.0%RH

    Test Points Optional40℃ /75%RH25℃ /60%RH30℃ /65%RH

    40℃ /25%RH25℃ /40%RH25℃ /60%RH

    Low Temperature Laboratory: 2 8℃

  • Walk-In Stability Chamber, Walk-In Stability test Chamber
    Walk-in Stability Test Chamber 20000SD
    Temp.:20~45℃, Humidity:20/40~80%RH
    The XCH-20000SD walk in chamber, newly airway system designed achieves uniform of temperature and humidity form different parts inside the chamber. The inner wall and duct plate are made of stainless steel 304. Observation window of hollow tempered glass with electrothermal film.


    Temperature Range: 20~ 45℃

    Temperature Fluctuation≤ ±0.5℃

    Temperature Deviation≤ ±1.0℃

    Humidity Range40~80%RH(or 2080%RH);

    Humidity Deviation≤ ±3.0%RH

    Test Points Optional40℃ /75%RH25℃ /60%RH30℃ /65%RH

    40℃ /25%RH25℃ /40%RH25℃ /60%RH

    Low Temperature Laboratory: 2 8℃

  • Walk-In Stability Chamber, Walk-In Stability test Chamber
    Walk-in Constant Temperature and Humidity Stability Chamber
    Temp.:20~45℃, Humidity:20/40~80%RH
    The XCH-8000SD Series Walk-In Stability test Chamber, newly airway system designed achieves uniform of temperature and humidity form different parts inside the chamber. The inner wall and duct plate are made of stainless steel 304. Observation window of hollow tempered glass with electrothermal film.


    Temperature Range: 20~ 45℃

    Temperature Fluctuation≤ ±0.5℃

    Temperature Deviation≤ ±1.0℃

    Humidity Range:20/40~80%RH(or 2080%RH);

    Humidity Deviation≤ ±3.0%RH

    Test Points Optional40℃ /75%RH25℃ /60%RH30℃ /65%RH

    40℃ /25%RH25℃ /40%RH25℃ /60%RH

    Low Temperature Laboratory: 2 8℃