Walk-in Stability Test Chamber 15000SD

XCH-15000SD Series humidity and temperature controlled chamber, newly airway system designed achieves uniform of temperature and humidity form different parts inside the chamber. The inner wall and duct plate are made of stainless steel 304. Observation window of hollow tempered glass with electrothermal film.


Model:XCH-15000SD

Temperature Range:20~45℃

  • Item no.:

    8000SD-40000SD

Walk-in Constant Temperature and Humidity Stability Chamber


Performance parameters:

Temperature Control

Temperature Fluctuation ≤ ±0.5℃,Temperature Deviation ≤ ±1.0℃

TEMP Range

20 - 45℃, Temperature Fluctuation:≤ ±0.5℃, Temperature Deviation:≤ ±1.0℃

Humidity Range
40 - 80%RH, Humidity Deviation:≤ ±3.0%RH(Customizable Humidity Range:20 ~ 80%RH)
Test Points Optional
25℃ /60%RH, 30℃ /65%RH( Low humidity : 40℃ /25%RH、25℃ /40%RH)
Environment temperature
+5~35℃
Low Temperature Laboratory
The cool storage can be customized under 20℃ and 2 ~ 8℃ cold storage (Temperature Fluctuation ≤ ±1.0℃,Temperature Deviation ≤ ±2.0℃ )
Reference Standard
Refer to GB/T 10586-2016, JJF1101-2019 environmental test equipment temperature and humidity calibration specification for technical conditions of hot and humid test chamber


Structure System:

The newly airway system designed achieves uniform of temperature and humidity form different parts inside the chamber. The inner wall and duct plate are made of stainless steel 304. Observation window of hollow tempered glass with electrothermal film. Illumination lamp, control panel with running indicator light and MIL malfunction indicator lamp.

Refrigerating System: 
Original imported refrigeration compressor unit with high performance, low noise and one work one back up.Control System:  Original imported programmable chromatic touch screen controller, sensitive, Small system error, Multi - stage program setting and multi - point accurate calibration function, With three level password;Humidity System: The world’s top VAISALA original imported humidity transducer with high precision,Low drift,Long-life and maintenance-free.

Data System: 
Needle micro printer,SD card storage and online electronic recording.Alarm System:   Sound-light alarm for temperature and humidity deviation, SMS alarm for remote temperature and humidity deviation and power failure, email alarm.

Safety Device:
The door is equipped with key safety lock and anti-reverse lock function to ensure the safety of users. The door frame is equipped with unique anti-condensation and anti-leakage device, compressor overload protection,  water shortage protection, anti-dry burning protection system, independent over-temperature protection system.

Electronic recording system:
Comply with the FDA 21 CFR Part Ⅱ law standard, Stable system performance, Audit tracking function, Three levels of user hierarchical authority management.


The Models of Walk-in Stability Chamber Details:

MODEL
TEMP RANGE(℃)
HUMIDITY RANGE
CAPACITY(L)

INTERNAL DIMEN(mm)

W×D×H

EXTERNAL DIMEN(mm)

W×D×H

POWER(KW) REMARKS
XCH-8000SD
20 ~ 45
40 ~ 80%
8000 1900×2200×2000
2100×3100×2300
5.0
Customizable Humidity: 20 ~ 80%RH 
XCH-15000SD
20 ~ 45
40 ~ 80%
15000 1900×4000×2000
2100×4900×2300
6.0
XCH-20000SD
20 ~ 45
40 ~ 80%
20000 2200×4100×2200
2400×4300×2400
6.5
XCH-40000SD
20 ~ 45
40 ~ 80%
40000 3600×5200×2200
3800×5400×2400
8.5

* Please consult the sales for specific technical parameters, XCH Biomedical reserves the right of explanation. Email: Christine@thchamber.com


Advantages:

Electronic recording system

Comply with the FDA 21 CFR Part Ⅱ law standard

Stable system performance

Audit tracking function customizable





HOW CAN WE HELP YOU?

Contact our sales team for a quotation. Email: Christine@thchamber.com

You can also leave us a message in the message box below.


Contact Now
Please fill in correct email address and phone number, to make it sure for us to reach you. Thanks.
Categories
Related Products
Walk-In Stability Chamber, Walk-In Stability test Chamber
The XCH-8000SD Series Walk-In Stability test Chamber, newly airway system designed achieves uniform of temperature and humidity form different parts inside the chamber. The inner wall and duct plate are made of stainless steel 304. Observation window of hollow tempered glass with electrothermal film. Temperature Range: 20~ 45℃ Temperature Fluctuation:≤ ±0.5℃ Temperature Deviation:≤ ±1.0℃ Humidity Range:20/40~80%RH(or 20~80%RH)); Humidity Deviation:≤ ±3.0%RH Test Points Optional:40℃ /75%RH、25℃ /60%RH、30℃ /65%RH (40℃ /25%RH、25℃ /40%RH、25℃ /60%RH) Low Temperature Laboratory: 2 ~ 8℃

View more

Walk-In Stability Chamber, Walk-In Stability test Chamber
The XCH-20000SD walk in chamber, newly airway system designed achieves uniform of temperature and humidity form different parts inside the chamber. The inner wall and duct plate are made of stainless steel 304. Observation window of hollow tempered glass with electrothermal film. Temperature Range: 20~ 45℃ Temperature Fluctuation:≤ ±0.5℃ Temperature Deviation:≤ ±1.0℃ Humidity Range:40~80%RH(or 20~80%RH)); Humidity Deviation:≤ ±3.0%RH Test Points Optional:40℃ /75%RH、25℃ /60%RH、30℃ /65%RH (40℃ /25%RH、25℃ /40%RH、25℃ /60%RH) Low Temperature Laboratory: 2 ~ 8℃

View more

Walk-In Stability Chamber, Walk-In Stability test Chamber
The XCH-40000SD Series newly airway system designed achieves uniform of temperature and humidity form different parts inside the chamber. The inner wall and duct plate are made of stainless steel 304. Observation window of hollow tempered glass with electrothermal film. Temperature Range: 20~ 45℃ Temperature Fluctuation:≤ ±0.5℃ Temperature Deviation:≤ ±1.0℃ Humidity Range:40~80%RH(or 20~80%RH)); Humidity Deviation:≤ ±3.0%RH Test Points Optional:40℃ /75%RH、25℃ /60%RH、30℃ /65%RH (40℃ /25%RH、25℃ /40%RH、25℃ /60%RH) Low Temperature Laboratory: 2 ~ 8℃

View more

Water Jacketed Incubator,Thermostatic Incubator,Constant Temperature Incubator
XCH-9160GHP Water jacketed incubator, Dedicated temperature controller, the temperature control accuracy error is small.Optional UV sterilization system can effectively kill the floating bacteria in the circulating air in the box。 Used for bacterial incubation, cultivation, ferment and other thermal experiments on hygiene, medicine, biochemistry, industry and agricultural science.The water jacketed incubator is an essential equipment for scientific research laboratories. Model: 9160GHP Temperature Fluctuation ≤ ±0.3℃ Temperature Uniformity ≤ ±0.5℃(@37℃) Timing Range: 1-9999min Power: AC 220V±10% 50HZ Environment temperature: +5 ~ 30℃

View more

Medicine Stability Testing Chamber,Temperature Humidity  Chamber, Medicine Testing Chamber
This 150L temperature and humidity test chamber, high quality stability chamber, using advanced high-quality components and manufacturing technology, stable and reliable performance, suitable for GMP certified users. Creates a temperature, humidity, light environment for drug, medicine and other products fields stability evaluation. Suitable for accelerated testing, long-term testing, wet test, climatic test and strong light irradiation test. Model: XCH-150SD Capacity:150L

View more

Walk-In Stability Chamber, Walk-In Stability test Chamber
The XCH-20000SD walk in chamber, newly airway system designed achieves uniform of temperature and humidity form different parts inside the chamber. The inner wall and duct plate are made of stainless steel 304. Observation window of hollow tempered glass with electrothermal film. Temperature Range: 20~ 45℃ Temperature Fluctuation:≤ ±0.5℃ Temperature Deviation:≤ ±1.0℃ Humidity Range:40~80%RH(or 20~80%RH)); Humidity Deviation:≤ ±3.0%RH Test Points Optional:40℃ /75%RH、25℃ /60%RH、30℃ /65%RH (40℃ /25%RH、25℃ /40%RH、25℃ /60%RH) Low Temperature Laboratory: 2 ~ 8℃

View more

Biomedical Refrigerator, pharmacy fridge, Medicine Refrigerator
The medical refrigerator is mainly used to store medicines, reagents, vaccines, biological products, blood products, etc., with a temperature range of 2-8°C, professional medical grade refrigerator. Model: 250BC~2000BC Temperature Control: Temperature Fluctuation ≤ ±1℃ ,Temperature Deviation ≤ ±2.0℃ Installed Power: AC220V±10% 50HZ Environment temperature: +5~35℃ Optional: Data storage and printing.SMS Alarm(With power off alarm)

View more

Water Jacketed Incubator,Thermostatic Incubator,Constant Temperature Incubator
XCH-9080GHP Water jacketed incubator, Dedicated temperature controller, the temperature control accuracy error is small.Optional UV sterilization system can effectively kill the floating bacteria in the circulating air in the box。 Used for bacterial incubation, cultivation, ferment and other thermal experiments on hygiene, medicine, biochemistry, industry and agricultural science.The water jacketed incubator is an essential equipment for scientific research laboratories. Model: 9080GHP Temperature Fluctuation ≤ ±0.3℃ Temperature Uniformity ≤ ±0.5℃(@37℃) Timing Range: 1-9999min Power: AC 220V±10% 50HZ Environment temperature: +5 ~ 30℃

View more

Medicine Stability Testing Chamber,Temperature Humidity Chamber, Medicine Testing Chamber
The XCH-3000SD Double Door Medicine Drug Stability Environmental Testing Chamber, using imported high-quality components and manufacturing technology, with Medicine Stability Chamber stable and reliable performance, suitable GMP certified users Model: XCH-3000SD TEMP Range: 10~65℃ TEMP Fluctuation: <±0.5℃ TEMP Deviation: < ±1.0℃ Humidity Range: 20 ~ 95% Humidity Deviation:< ±3%RH Capacity: 800L~3000L Environment temperature: +5 ~ 35℃

View more

Contact Now

Contact Now

Home

Products

Email

whatsapp